现代矿业 ›› 2024, Vol. 40 ›› Issue (02): 24-26.

• • 上一篇    下一篇

手持式X射线荧光分析仪在某铁矿山井下矿石的质量检测

在矿山地质工作过程中,井下矿石品位是区分矿岩、地质圈定、矿石损失贫化等诸多生
产环节的重要数据依据,而井下矿石品位数据主要靠化学分析试验获得。介绍了手持式X射线荧光
分析仪在某地下铁矿应用的可行性研究情况。结果表明:手持式X荧光分析仪对样品铁品位分析几
乎不受干湿影响;井下巷道检测表明,化验值与校正值的总体变化趋势基本一致,但存在较大偏差;
井下区分矿岩的准确率达100%,区分效果良好。
  

  1. 五矿矿业控股有限公司
  • 出版日期:2024-02-18 发布日期:2024-08-13

Quality Detection of Hand-held X-ray Fluorescence Analyzer in Underground Iron Ore

In the process of mine geological work,the underground ore grade is an important data ba⁃
sis for distinguishing ore rock,geological delineation,ore loss dilution and many other production links,
while the underground ore grade data are mainly obtained by chemical analysis test.The feasibility study situ⁃
ationof the application of hand-held X-ray fluorescence analyzer in an underground iron mine is introduced.
The results show that the analysis of iron grade by hand-held X-ray fluorescence analyzer is almost not af⁃
fected by dry and wet.The detection of underground roadway shows that the overall change trend of the test
value and the corrected value is basically the same,but there is a large deviation. The accuracy rate of un⁃
derground distinguishing ore rock is 100%,and the distinguishing effect is good.
  

  1. Minmetals Mining Holding Co.,Ltd.
  • Online:2024-02-18 Published:2024-08-13

摘要:

在矿山地质工作过程中,井下矿石品位是区分矿岩、地质圈定、矿石损失贫化等诸多生
产环节的重要数据依据,而井下矿石品位数据主要靠化学分析试验获得。介绍了手持式X射线荧光
分析仪在某地下铁矿应用的可行性研究情况。结果表明:手持式X荧光分析仪对样品铁品位分析几
乎不受干湿影响;井下巷道检测表明,化验值与校正值的总体变化趋势基本一致,但存在较大偏差;
井下区分矿岩的准确率达100%,区分效果良好。

Abstract:

In the process of mine geological work,the underground ore grade is an important data ba⁃
sis for distinguishing ore rock,geological delineation,ore loss dilution and many other production links,
while the underground ore grade data are mainly obtained by chemical analysis test.The feasibility study situ⁃
ationof the application of hand-held X-ray fluorescence analyzer in an underground iron mine is introduced.
The results show that the analysis of iron grade by hand-held X-ray fluorescence analyzer is almost not af⁃
fected by dry and wet.The detection of underground roadway shows that the overall change trend of the test
value and the corrected value is basically the same,but there is a large deviation. The accuracy rate of un⁃
derground distinguishing ore rock is 100%,and the distinguishing effect is good.

Key words: