欢迎访问《现代矿业》杂志官方网站,今天是 分享到:
×

扫码分享

现代矿业 ›› 2026, Vol. 42 ›› Issue (05): 123-128.

• 岩土工程 • 上一篇    下一篇

某铁尾矿坝土工织物滤层淤堵特性试验研究

杨 龙1 汪万升2 张祖刚1 欧张文1 吴海民2   

  1. 1. 南京宝地梅山产城发展有限公司矿业分公司;2. 河海大学水利水电学院
  • 出版日期:2026-05-25 发布日期:2026-06-16

Experimental Study on Clogging Characteristics of Geotextile Filter Layer of an Iron Tailings Dam

  1. 1. Mining Branch of Nanjing Baodi Meishan Industrial City Development Co.,Ltd.; 2. College of Water Conservancy and Hydropower Engineering,Hohai University
  • Online:2026-05-25 Published:2026-06-16

摘要: 为明确细颗粒含量较高的铁尾矿坝中土工织物的淤堵特性,寻找更适合铁尾矿坝的 土工织物类型,通过改进梯度比试验,对短纤、长丝和滤布 3 种土工织物与某铁尾矿泥浆组成的系 统进行渗透试验,通过分析梯度比和系统渗透系数的变化规律,结合试验后对土工织物滤层颗粒 运移变化规律分析,揭示机械淤堵机理。同时,对试验土样进行化学成分检测,揭示化学淤堵机 理。研究结果表明:随着水力梯度的增大,短纤和滤布土工织物表现出了较为优异的反滤性能,而 长丝土工织物则出现了较为严重的淤堵现象。试验结束后,滤布土工织物滤层中部形成了良好的 反滤层。化学淤堵主要是由于铁尾矿中 Fe2+ 发生氧化反应生成 Fe(OH)₃胶体所致。Fe2+ 转变成 Fe3+ 的速率依次为短纤 > 长丝 > 滤布,滤布土工织物表现出了良好的抗化学淤堵性能,更适用于铁尾矿 坝工程。

关键词: 铁尾矿, 土工织物, 反滤, 梯度比试验, 机械淤堵, 化学淤堵

Abstract: In order to clarify the clogging characteristics of geotextiles in iron tailings dam with high content of fine particles,and to find a more suitable type of geotextile for iron tailings dam,the permeabili⁃ ty test of the system composed of three kinds of geotextiles(short fiber,filament yarns and filter cloth) and an iron tailings slurry is carried out by improving the gradient ratio test. By analyzing the variation law of gradient ratio and system permeability coefficient,combined with the analysis of the variation law of par⁃ ticle migration in geotextile filter layer after the test,the mechanical clogging mechanism is revealed.At the same time,the chemical composition of the test soil samples is tested to reveal the chemical clogging mech⁃ anism.The results show that with the increase of hydraulic gradient,the geotextiles of short fiber and filter cloth show excellent reverse filtration performance,while the geotextiles of filament yarns show more seri⁃ ous clogging phenomenon.After the test,a good reverse filter layer is formed in the middle of the filter cloth geotextile filter layer. The chemical clogging is mainly caused by the oxidation reaction of Fe2+ in iron tailings to form Fe(OH)3 colloid.The conversion rate of Fe2+ to Fe3+ is in the order of short fiber> filament yarns > filter cloth. The filter cloth geotextile shows good resistance to chemical clogging and is more suit⁃ able for iron tailings dam project.

Key words: iron tailings, geotextiles, reverse filter, gradient ratio test, mechanical clogging, chemi? cal clogging