摘要: 在长距离独头巷道施工过程中,各种作业的进行,极易导致巷道内空气指标超标,当独 头巷道长度继续延伸时,原有的压入式通风方式已经无法满足井下通风要求。为解决长距离独头巷 道通风难题,在理论计算的基础上,采取 Ventsim 软件对长距离独头巷道进行通风模拟,分别对独头 巷道在1 500,2 200,3 554 m里程条件下进行压入式通风、抽出式通风、混合式通风及混合式+风幕机通 风模拟,从风量、总风阻及风网效率进行分析。结果表明,独头巷道里程低于1 500 m,采用单台22 kW 风机进行压入式通风,风量为 9.4 m3 /s,总风阻为 20.917 N·s 2 /m8 ,风网效率为 55.8%;巷道里程达到 2 200 m后,采用3台22 kW风机进行混合式通风,风量为13.2 m3 /s,总风阻为41.647 N·s 2 /m8 ,风网效率 为80.4%;巷道里程达到3 554 m,采用混合式+风幕机通风,风量为15.2 m3 /s,总风阻为81.186 N·s 2 /m8 , 风网效率为71.3%。模拟结果用于工程实践中,采取混合式+风幕机通风方式,有效解决了长距离独 头巷道通风难题。

关键词: 长距离独头巷道, 通风计算, Ventsim软件

Abstract: In the construction process of long-distance single-head roadway,due to the conduct of various operations,it is easy to cause the air index in the roadway to exceed the standard. When the length of the single-head roadway continues to extend,the original pressure ventilation method has been unable to meet the requirements of underground ventilation. In order to solve the ventilation problem of long-distance single-head roadway,on the basis of theoretical calculation,Ventsim software is used to simulate the venti⁃ lation of long-distance single-head roadway. The forced ventilation,extraction ventilation,mixed ventila⁃ tion and mixed + air curtain machine ventilation simulations are carried out under the conditions of 1 500 m, 2 200 m and 3 554 m,respectively. The air volume,total air resistance and air network efficiency are ana⁃ lyzed. The results show that the mileage of the single-head roadway is less than 1 500 m,and a single 22 kW fan is used for forced ventilation. The air volume is 9.4 m3 /s,the total air resistance is 20.917 N·s 2 /m8 ,and the air network efficiency is 55.8%. After the roadway mileage reached 2 200 m,three 22 kW fans were used for hybrid ventilation. The air volume was 13.2 m3 /s,the total air resistance was 41.647 N·s 2 /m8 ,and the air network efficiency was 80.4%. The roadway mileage reaches 3 554 m,and the mixed + air curtain machine is used for ventilation. The air volume is 15.2 m3 /s,the total air resistance is 81.186 N·s 2 /m8 ,and the ventilation efficiency is 71.3%.The simulation results are used in engineering practice, and the ventila⁃ tion mode of hybrid + air curtain machine is adopted, which effectively solves the ventilation problem of long-distance single-head roadway.

Key words: long-distance single-head roadway, ventilation calculation, Ventsim software