摘要: 为给某钼矿选矿厂扩建新系统提供设计依据,按现场高效选矿系统流程,在实验室进 行了流程再现试验,并同步进行了现场流程考察。结果表明:①实验室试验指标能充分揭示矿物的 可选性,可作为工业生产指标设计依据;②验证试验与工业生产钼粗选回路回收率差异大,设计应根 据试验指标进行适当修正,而验证试验与工业生产钼精选回路回收率接近,可作为设计依据;③工业 浮选柱富集比高,更有利于精矿品位的提高;④浮选柱选矿效率显著高于浮选机,浮选柱1 次精选相 当于浮选机2~3 次精选,因此,适当的工业浮选柱精选流程较实验室小型浮选机浮选流程更简洁、稳 定、可靠。

关键词: 实验室再现试验, 浮选柱, 浮选机, 工艺指标

Abstract: In order to provide the design basis for the new system expansion of a molybdenum concentrator,according to the process of high efficiency beneficiation system in site,the process reproduction test was carried out in the laboratory,and the field process investigation was carried out simultaneously. The results showed that: ①the laboratory test indexes can fully reveal the mineral separability,which can be used as the basis for industrial production index design; ②There is a great difference in recovery rate between verification test and industrial molybdenum roughage circuit,so the design should be modified according to the test index. While the recovery rate of the verification test is close to that of the industrial production,which can be used as the design basis; ③Higher concentration ratio of industrial flotation column is more beneficial to the improvement of concentrate grade; ④ The beneficiation efficiency of the flotation column is significantly higher than that of the flotation machine. One selection of flotation column is equivalent to two or three selection of flotation machine. Therefore,the proper process of industrial flotation column is more con⁃ cise,stable and reliable than that of the small flotation machine in the laboratory.

Key words: laboratory reappearance test, flotation column, flotation machine, process indexes